The following describes the interface under driver control.
SEL1B-, SEL2B-, SEL3B-
Select lines for the three external disk drives active low.
TK0-
A selected drive pulls this signal low whenever its read-write head
is on track 00.
RDY-
When a disk drive's motor is on, this line indicates the selected
disk is installed and rotating at speed. The driver ignores this
signal. When the motor is off this is used as a id data line. see
below.
WPRO- (Pin #14)
A selected drive pulls this signal low whenever it has a
write-protected diskette installed.
INDEX- (Pin #22)
A selected drive pulses this signal low once for each revolution of
its motor.
SIDEB- (Pin #13)
The system drives this signal to all disk drives -- low for side 1,
high for side 0.
STEPB- (Pin #18)
Pulsed to step the selected drive's head.
DIRB (Pin #19)
The system drives this signal high or low to tell the selected drive
which way to step when the STEPB- pulse arrives. Low means step in
(to higher-numbered track); high means step out.
DKRD- (Pin #2)
A selected drive will put out read data on this line.
DKWDB- (Pin #17)
The system drives write data to all disks via this signal. The data
is only written when DKWEB- is active (low). Data is written only to
selected drives.
DKWEB- (Pin #16)
This signal causes a selected drive to start writing data (provided
by DKWDB-) onto the disk.
CHNG- (Pin #11)
A selected drive will drive this signal low whenever its internal
"disk change" latch is set. This latch is set when the drive is first
powered on, or whenever there is no diskette in the drive. To reset
the latch, the system must select the drive, and step the head. Of
course, the latch will not reset if there is no diskette installed.
MTRXD- (Pin #8)
This is the motor control line for all four disk drives. When the
system wants to turn on a disk drive motor, it first deselects the
drive (if selected), pulls MTRXD- low, and selects the drive. To turn
the motor off, the system deselects the drive, pulls MTRXD- high, and
selects the drive. The system will always set MTRXD- at least 1.4
microseconds before it selects the drive, and will not change MTRXD-
for at least 1.4 microseconds after selecting the drive. All external
drives must have logic equivalent to a D flip-flop, whose D input is
the MTRXD- signal, and whose clock input is activated by the
off-to-on (high-to-low) transition of its SELxB- signal. As noted
above, both the setup and hold times of MTRXD- with respect to SELxB-
will always be at least 1.4 microseconds. The output of this
flip-flop controls the disk drive motor. Thus, the system can control
all four motors using only one signal on the cable (MTRXD-).
DRESB- (Pin #10)
This signal is a buffered version of the system reset signal. Three
things can make it go active (low):
* System power-up (DRESB- will go low for approximately one
second);
* System CPU executes a reset instruction (dresb- will go low for
approximately 17 microseconds);
* hard reset from keyboard (lasts as long as keyboard reset is
held down).
External disk drives should respond to DRESB- by shutting off their
motor flip-flops and write protecting themselves.
A level of 3.75v or below on the 5v+ requires external disks to